Land Off Abbotts Lane And Upper Hill Street, Coventry, CV1 4DF Data via plota.co.uk

PL/2026/0001183/DCA - DCA Approval of details reserved by condition Approved

Proposal

Submission of details to discharge conditions 11 in part - (drainage/ SuDS,) 13 in part -(CMP), 15 in part - (CEMP) 22 in part - (LLBS) and 26 - (site-wide phasing programme): imposed on planning permission PL/2025/0002447/RVC granted on 24/02/2026 for Hybrid planning application for up to 690 new homes comprising: (i) Full planning application for up to 212 dwellings (Class C3) served via access from Abbotts Lane and Upper Hill Street; strategic landscaping and earthworks; temporary car parking; surface water drainage and all other ancillary and enabling works, and: (ii) Outline planning application for new residential development (Class C3); ancillary Class E development of up to 950 sqm of floorspace; strategic landscaping and earthworks; surface water drainage; and all other ancillary infrastructure and enabling site works with means of access to be taken from the connections from Abbotts Lane and Upper Hill Street (part of the full application) for consideration; all other matters (layout, appearance, scale, and landscaping) reserved for subsequent approval. (Variation of condition No. 5 (approved drawings) to allow revisions to scheme to address current fire safety regulations and scheme viability; imposed on planning permission reference granted on 01/08/2025) Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
4 Jul 2026
✓
Validated
6 Jul 2026
✓
Approved
18 Sept 2026

Approved on 18 Sept 2026 · Delegated decision · Last checked 30 Sept 2026

Documents 49

Statements & assessments 32

PDF DRAINAGE-LAYOUT-SHEET-1 DWG 211103-EDGE-XX-XX-DR-C-2001 Rev P07 Drainage · 18 Sept 2026 View ↗ PDF DRAINAGE-LAYOUT-SHEET-2 DWG 211103-EDGE-XX-XX-DR-C-2002 Rev P07 Drainage · 18 Sept 2026 View ↗ PDF TRANSMITTAL-211103-ABBOTS-LANE-RESIDENTIAL-260916-01 Drainage · 18 Sept 2026 View ↗ PDF EXCEEDANCE-ROUTE-PLANP DWG 211103-EDGE-XX-XX-DR-C-2011 Rev P03 Drainage · 18 Sept 2026 View ↗ PDF Hydro-Brake Specifications DWG SHE-0106-5400-1200-5400 Drainage · 4 Sept 2026 View ↗ PDF Hydro-Brake Technical Specification DWG SHE-0106-5400-1200-5400 Drainage · 4 Sept 2026 View ↗ PDF Drainage Maintenance Plan Drainage · 4 Sept 2026 View ↗ PDF Surface Water Pipe Network Drainage · 4 Sept 2026 View ↗ PDF Tank Details DWG 211103-EDGE-XX-XX-DR-C-3204 Rev P02 Drainage · 4 Sept 2026 View ↗ PDF Drainage Construction Details - Sheet 2 DWG 211103-EDGE-XX-XX-DR-C-3203 Rev P02 Drainage · 4 Sept 2026 View ↗ PDF Drainage Construction Details - Sheet 1 DWG 211103-EDGE-XX-XX-DR-C-3202 Rev P03 Drainage · 4 Sept 2026 View ↗ PDF Hydrobrake Details DWG 211103-EDGE-XX-XX-DR-C-2202 Rev P02 Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Catchment Plan DWG 211103-EDGE-XX-XX-DR-C-2300 Rev P01 Drainage · 4 Sept 2026 View ↗ PDF Manhole Schedules DWG 211103-EDGE-XX-XX-DR-C-2201 Rev P07 Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Exceedance Route Plan DWG 211103-EDGE-XX-XX-DR-C-2011 Rev P02 Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Drainage Layout - Sheet 1 DWG 211103-EDGE-XX-XX-DR-C-2001 Rev P06 Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Drainage Layout - Sheet 2 DWG 211103-EDGE-XX-XX-DR-C-2002 Rev P06 Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Finished Levels Plan - Sheet 2 DWG 211103-EDGE-XX-XX-DR-C-1002 Rev P01 Drainage · 4 Sept 2026 View ↗ PDF Response to LLFA comments Drainage · 4 Sept 2026 View ↗ PDF Plot 3 and 4 Finished Levels Plan - Sheet 1 DWG 211103-EDGE-XX-XX-DR-C-1001 Rev P01 Drainage · 4 Sept 2026 View ↗ PDF Drainage Diversion Information DWG 19820-EDGE-XX-XX-DR-C-2003 Rev P09 Drainage · 4 Sept 2026 View ↗ PDF Drainage Maintenance Plan Drainage · 7 Jul 2026 View ↗ PDF Flood Risk Assessment Flood risk assessment · 7 Jul 2026 View ↗ PDF Tank Details DWG 211103-EDGE-XX-XX-DR-C-3204-P01 Drainage · 6 Jul 2026 View ↗ PDF Surface Water Network 2020.1.3: 100 Year 40CC Simulation Drainage · 6 Jul 2026 View ↗ PDF Surface Water Network 2020.1.3: 30 Year Simulation Drainage · 6 Jul 2026 View ↗ PDF Surface Water Network 2020.1.3: 2 Year Simulation Drainage · 6 Jul 2026 View ↗ PDF Manhole Schedule DWG 211103-EDGE-XX-XX-DR-C-2201-P05 Drainage · 6 Jul 2026 View ↗ PDF Plot 3 and 4: Drainage Layout Sheet 2 DWG 211103-EDGE-XX-XX-DR-C-2002-P05 Drainage · 6 Jul 2026 View ↗ PDF Plot 3 and 4: Drainage Layout Sheet 1 DWG 211103-EDGE-XX-XX-DR-C-2001-P05 Drainage · 6 Jul 2026 View ↗ PDF Drainage Construction Details Sheet 2 DWG 211103-EDGE-XX-XX-DR-C-3203-P02 Drainage · 6 Jul 2026 View ↗ PDF Drainage Construction Details Sheet 1 DWG 211103-EDGE-XX-XX-DR-C-3202-P02 Drainage · 6 Jul 2026 View ↗

All documents on the council site ↗

Associated applications 6

Site constraints 9

Article 4 direction
HMO - 30.9.23. Named permitted development rights are withdrawn here.
An Article 4 direction withdraws particular permitted development rights, so work that would normally need no application needs one here. Not every council has published its directions.
Air quality management area: Coventry City-Wide AQMA
The council has declared the area as failing an air quality objective.
Schemes that add traffic, parking or combustion plant are assessed against the area's action plan and may need an air quality assessment.
Council record ↗
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Also on the record
Conservation area 69 m away: Naul's Mill Conservation Area; 1 listed building within 150 m; Coalfield, development low risk area; Scheduled monument 246 m away: Coventry city walls; Heritage at risk 69 m away: Naul's Mill, Coventry; Inside the Coventry built-up area.
Not affected
Outside flood zones 2 and 3 · Not green belt

Checked on 2 November 2026. Historic England, the Environment Agency, Natural England, the Mining Remediation Authority, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Coventry - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Coventry
Application type
DCA Approval of details reserved by condition
Postcode
CV1 4DF
Received
4 Jul 2026
Validated
6 Jul 2026
Ward
Sherbourne
Case officer
Show
Target decision
18 Sept 2026
Decision
Granted No Conditions
Decision date
18 Sept 2026
Decision level
Delegated decision
Applicant
Show
Agent
Twenty5 Planning Ltd

Consultation & key dates

Statutory expiry
18 Sept 2026
Coventry
Planning Authority Score
7.7/10
Good
#35 of 296 overall
Relevant to this application:
Major dwellings

Coventry is one of the fastest councils in England for householder decisions: #13 of 296 on speed. Only 13% of applications have the time limit extended, well below the 41% national average - the council usually decides on time. Householder applications are slightly more likely to be approved here (90%) than the national average (90%).

Among the fastest councils in England
for householder decisions
These figures are council-wide context, not a prediction for this application. View full council performance
Coventry decision statistics
Based on MHCLG data, the year to March 2026
84%
Overall approval rate
Below avg (87%) #219 of 296
90%
Householder approved
Above avg (90%) #189 of 296
91%
Decided in 8 weeks
Above avg (63%) #13 of 296
13%
Extended time limit
Below avg (41%) #7 of 296
72%
Minor dwellings approved
114 decided (1-9 homes)
89%
Major dwellings approved
28 decided (10+ homes)
74%
Change of use approved
100 decided
1,131
Total decisions
186 refused in the year to March 2026