1,5,8,10,13,15,19,24,25,28,32 Darfield - WN8 0AT 3,5,8,10,12,14,15,23 Danbers - WN8 0AT 3,17,23 - Daybrook… Data via plota.co.uk

2025/1025/FUL - Full Planning Application Registered

Proposal

Existing flat roofs to be replaced with low pitched roofs with new rainwater goods, external wall insulation, window and door replacements with like for like designs. This application covers Chequer Lane, Danbers, Darfield, Daybrook Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
2 Dec 2025
✓
Validated
11 Dec 2025
✓
Consultation
23 Jul 2026
Decision
Expected by 5 Feb 2026

Under consideration

No decision has been issued yet. Plota predicted a decision soon after comments close on 6 Aug 2026; it is now day 302.

The consultation period closed on 6 Aug 2026.

Documents 22

Consultation & comments 3

PDF Objector’s name hidden Show Neighbour & Interested Party Representation · 14 Jan 2026 View ↗
PDF Objector’s name hidden Show Neighbour & Interested Party Representation · 14 Jan 2026 View ↗
PDF Consultation/neighbours notified Consultations & Neighbours notified · 17 Dec 2025 View ↗

All documents on the council site ↗

Site constraints 6

Habitat network: Network Enhancement Zone 2
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Also on the record
SSSI 275 m away: Ravenhead Brickworks SSSI; Coalfield, development low risk area; 2 listed buildings within 150 m; Inside the Orrell built-up area.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 6 October 2026. Historic England, the Environment Agency, Natural England, the Mining Remediation Authority, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area113 m² (1,216 sq ft)
Energy ratingD (62 out of 100), could reach B
PropertyMid-terrace bungalow, 5 habitable rooms
Built1967 to 1975
HeatingBoiler and radiators, mains gas
WallsCavity wall, filled cavity

From the energy performance certificate lodged in February 2023, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in West Lancashire - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Full Planning Application
Postcode
WN8 0DA
Received
2 Dec 2025
Validated
11 Dec 2025
Ward
Up Holland Ward
Parish
Up Holland
Case officer
Show
Decision level
Delegated unless Member request to Cttee
Applicant
Show
Agent
Coactivation LTD

Decision outlook

Day 302, past the statutory target. 81% of full applications in West Lancashire are decided within thirteen weeks; extensions of time are common, and the council need not decide on the day. Last seen undecided on 3 Oct 2026.

Day 302246 days past the 56-day target
38%decided within 8 weeks
85%approved
268decided in the last year

Plota live figures for full applications decided by West Lancashire in the last twelve months, from validation. West Lancashire decision record →

Public comments

No public comments yet.

56 neighbours consulted · Last counted 3 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-14377773
Planning Portal ref
PP-14377773
Neighbours
23 Jul 2026
Consultation
23 Jul 2026
Comments by
6 Aug 2026
Env. assessment
No
West Lancashire
Planning Authority Score
1.1/10
Poor
#291 of 296 councils
Relevant to this application:
Householder decisions

West Lancashire is slower than most councils at deciding householder applications, ranking #265 out of 296. The council extends the time limit on 60% of applications - one of the highest rates in England. Expect your application to take longer than the standard deadline. West Lancashire is also one of the strictest councils - it refuses more householder applications than almost any other, with only 85% approved vs 90% nationally.

One of the strictest councils
only 85% approved vs 90% nationally
These figures are council-wide context, not a prediction for this application. View full council performance
West Lancashire decision statistics
Based on MHCLG data, the year to March 2026
82%
Overall approval rate
Below avg (87%) #253 of 296
85%
Householder approved
Below avg (90%) #252 of 296
41%
Decided in 8 weeks
Below avg (63%) #265 of 296
60%
Extended time limit
Above avg (41%) #271 of 296
73%
Minor dwellings approved
62 decided (1-9 homes)
60%
Major dwellings approved
5 decided (10+ homes)
59%
Change of use approved
34 decided
564
Total decisions
103 refused in the year to March 2026

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.