Hull City Council City Treasury Guildhall Road Kingston Upon Hull HU1 2AB Data via plota.co.uk

25/00572/FULL - Full Planning Permission Approved

Proposal

External alterations to building involving:- 1. Installation of windows, doors curtain walling, and louvres to replace existing windows, doors curtain walling and louves. 2. Installation of photovoltaic solar panels to south-facing roof slope. 3. Erection of substation to eastern end of building. 4. Formation of ramp area to south elevation, and other minor works. (Revised description) Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
24 Jun 2025
✓
Validated
4 Dec 2025
✓
Approved
21 Apr 2026

Approved on 21 Apr 2026 · Delegated Decision · Last checked 4 Oct 2026

Documents 78

Plans & drawings 61

PDF AMENDED EXISTING ELEVATIONS Drawing · 9 Mar 2026 View ↗ PDF AMENDED PROPOSED ROOF PLANS Drawing · 9 Mar 2026 View ↗ PDF AMENDED WINDOWS SCHEDULE CURTAIN WALLING SECOND AND THIRD FLOOR Drawing · 9 Mar 2026 View ↗ PDF AMENDED DOOR SCHEDULE ELEVATIONS SHEET 1 Drawing · 9 Mar 2026 View ↗ PDF AMENDED WINDOWS SCHEDULE ELEVATIONS SHEET 1 Drawing · 9 Mar 2026 View ↗ PDF AMENDED WINDOWS SCHEDULE ELEVATIONS SHEET 2 Drawing · 9 Mar 2026 View ↗ PDF AMENDED WINDOWS SCHEDULE ELEVATIONS SHEET 3 Drawing · 9 Mar 2026 View ↗ PDF AMENDED WINDOWS SCHEDULE CURTAIN WALLING GROUND AND FIRST FLOOR Drawing · 9 Mar 2026 View ↗ PDF AMENDED PROPOSED ELEVATIONS Drawing · 9 Mar 2026 View ↗ PDF AMENDED DOOR SCHEDULE ELEVATIONS SHEET 2 Drawing · 9 Mar 2026 View ↗ PDF REVISED SITE LOCATION PLAN AND BLOCK PLANS Drawing · 19 Dec 2025 View ↗ PDF EXISTING ROOF PLAN Drawing · 16 Oct 2025 View ↗ PDF EXISTING SECOND FLOOR GEN ARRANGEMENT Drawing · 16 Oct 2025 View ↗ PDF EXISTING THIRD FLOOR GEN ARRANGEMENT Drawing · 16 Oct 2025 View ↗ PDF PROPOSED GROUND FLOOR GA PLAN Drawing · 16 Oct 2025 View ↗ PDF SUPERSEDED SITE LOCATION AND BLOCK PLANS Drawing · 16 Oct 2025 View ↗ PDF EXISTING GROUND FLOOR GEN ARRANGEMENT Drawing · 16 Oct 2025 View ↗ PDF EXISTING FIRST FLOOR GEN ARRANGEMENT Drawing · 16 Oct 2025 View ↗ PDF EXISTING BUILDING SECTIONS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED BUILDING SECTIONS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED GROUND FLOOR REMEDIAL WORKS Drawing · 16 Oct 2025 View ↗ PDF WINDOW SCHEDULE ELEVATIONS SHEET 2 Drawing · 16 Oct 2025 View ↗ PDF WINDOW SCHEDULE ELEVATIONS SHEET 3 Drawing · 16 Oct 2025 View ↗ PDF CURTAIN WALLING SECOND AND THIRD FLOOR Drawing · 16 Oct 2025 View ↗ PDF DOOR SCHEDULE GROUND AND FIRST FLOOR Drawing · 16 Oct 2025 View ↗ PDF DOOR SCHEDULE SECOND AND THIRD FLOOR Drawing · 16 Oct 2025 View ↗ PDF PROPOSED ELECTRICAL SUB STATION Drawing · 16 Oct 2025 View ↗ PDF PROPOSED ELECTRICAL SUB STATION AREA PLANS AND ELEVATIONS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED FIRST FLOOR GA PLAN Drawing · 16 Oct 2025 View ↗ PDF PROPOSED SECOND FLOOR GA Drawing · 16 Oct 2025 View ↗ PDF PROPOSED THIRD FLOOR GA Drawing · 16 Oct 2025 View ↗ PDF PROPOSED ROOF PLAN Drawing · 16 Oct 2025 View ↗ PDF PROPOSED GROUND FLOOR DIMENSION LAYOUT Drawing · 16 Oct 2025 View ↗ PDF PROPOSED FIRST FLOOR DIMENSION LAYOUT Drawing · 16 Oct 2025 View ↗ PDF PROPOSED SECOND FLOOR DIMENSION LAYOUT Drawing · 16 Oct 2025 View ↗ PDF PROPOSED THIRD FLOOR DIMENSION LAYOUT Drawing · 16 Oct 2025 View ↗ PDF EXISTING ELEVATIONS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED ELEVATIONS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED FENESTRATION DOOR AND LOUVRE ELEVS Drawing · 16 Oct 2025 View ↗ PDF WINDOW SCHEDULE ELEVATIONS SHEET 1 Drawing · 16 Oct 2025 View ↗ PDF CURTAIN WALLING GROUND AND FIRST FLOOR Drawing · 16 Oct 2025 View ↗ PDF DOOR SCHEDULE ELEVATIONS SHEET 1 Drawing · 16 Oct 2025 View ↗ PDF DOOR SCHEDULE ELEVATIONS SHEET 2 Drawing · 16 Oct 2025 View ↗ PDF PROPOSED EXTERNAL WORKS Drawing · 16 Oct 2025 View ↗ PDF PROPOSED AIR HANDLING UNIT COMPOUND Drawing · 24 Jun 2025 View ↗ PDF PROPOSED FENESTRATION, DOOR & LOUVRE REFRENCE ELEVATIONS Drawing · 24 Jun 2025 View ↗ PDF -EXISTING ELEVATIONS Drawing · 24 Jun 2025 View ↗ PDF PROPOSED FLOOR & ROOF PLANS Drawing · 24 Jun 2025 View ↗ PDF PROPOSED ROOF PLAN Drawing · 24 Jun 2025 View ↗ PDF PROPOSED THIRD FLOOR GA. Drawing · 24 Jun 2025 View ↗ PDF PROPOSED SECOND FLOOR GA Drawing · 24 Jun 2025 View ↗ PDF -PROPOSED FIRST FLOOR GA Drawing · 24 Jun 2025 View ↗ PDF EXISTING FLOOR & ROOF PLANS Drawing · 24 Jun 2025 View ↗ PDF EXISTING SECOND FLOOR GENERAL ARRANGEMENT Drawing · 24 Jun 2025 View ↗ PDF EXISTING FIRST FLOOR GENERAL ARRANGEMENT. Drawing · 24 Jun 2025 View ↗ PDF EXISTING GROUND FLOOR GENERAL ARRANGEMENT Drawing · 24 Jun 2025 View ↗ PDF SITE LOCATION & BLOCK PLANS Drawing · 24 Jun 2025 View ↗ PDF PROPOSED GROUND FLOOR GA Drawing · 24 Jun 2025 View ↗ PDF EXISTING ROOF PLAN Drawing · 24 Jun 2025 View ↗ PDF EXISTING THIRD FLOOR GENERAL ARRANGEMENT Drawing · 24 Jun 2025 View ↗ PDF PROPOSED ELEVATIONS Drawing · 24 Jun 2025 View ↗

All documents on the council site ↗

Associated applications 2

  • FullApproved25/00572/FULLThis application
    External alterations to building involving:- 1. Installation of windows, doors curtain walling, and louvres to replace existing…

    Conditions 6, 7, 8 awaiting decision

Site constraints 6

Flood zone 3, rivers and sea
High chance: a 1 in 100 or greater annual chance from rivers, or 1 in 200 from the sea. Any development here needs a flood risk assessment. Defences are not counted.
The Environment Agency flood map for planning. Homes in zone 3 must also pass the sequential test. Surface water flooding is a separate map.
Flood map ↗
Old Town conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Council document ↗
National infrastructure project 198 m away: A63 Castle Street Improvement-Hull
The site is 198 m from the project boundary. Highway, decided. The project page says whether consent was granted.
Nationally significant infrastructure projects (power stations, electricity lines, pipelines, major roads and railways, harbours, airports and reservoirs) are consented by a Secretary of State under the Planning Act 2008, after an examination by the Planning Inspectorate, rather than by the council. The boundary is the one the Inspectorate consults on and can change as the scheme does. Projects are shown within 2 km of the site.
Planning Inspectorate project page ↗
43 listed buildings within 150 m
Nearest: White Hart Hotel, Grade II, 24 m away · 2 Grade II*, 41 Grade II
The site itself is not listed. Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show all 43 with distances
Historic England ↗
Also on the record
Scheduled monument 233 m away: Beverley Gate and adjacent archaeological remains forming part of Hull's medieval and post-medieval defences; Inside the Kingston upon Hull built-up area.
Not affected
Not green belt

Checked on 2 November 2026. Historic England, the Environment Agency, Natural England, the Planning Inspectorate and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Hull - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Hull
Application type
Full Planning Permission
Postcode
HU1 2AB
Received
24 Jun 2025
Validated
4 Dec 2025
Ward
St Andrews And Dockland
Case officer
Show
Decision
Application Permitted
Decision date
21 Apr 2026
Decision level
Delegated Decision
Agent
Hull City Council

How this decision compares

Decided in 138 days from validation, 56 days slower than Hull's median of 82 for full applications. Approved, as 92% of full applications here are.

34%decided within 8 weeks
92%approved
309decided in the last year

Plota live figures for full applications decided by Hull in the last twelve months, from validation. Hull decision record →

Public comments

No public comments yet.

6 neighbours consulted · Last counted 4 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
EM
Comments by
4 Feb 2026
Env. assessment
No
Hull
Planning Authority Score
2.6/10
Poor
#248 of 296 councils
Relevant to this application:
Householder decisions

Hull is slower than most councils at deciding householder applications, ranking #231 out of 296. The council extends the time limit on 62% of applications - one of the highest rates in England. Expect your application to take longer than the standard deadline. Householder applications are slightly more likely to be approved here (92%) than the national average (90%).

Frequently extends decision deadlines
expect longer than the statutory limit
These figures are council-wide context, not a prediction for this application. View full council performance
Hull decision statistics
Based on MHCLG data, the year to March 2026
92%
Overall approval rate
Above avg (87%) #85 of 296
92%
Householder approved
Above avg (90%) #156 of 296
51%
Decided in 8 weeks
Below avg (63%) #231 of 296
62%
Extended time limit
Above avg (41%) #273 of 296
88%
Minor dwellings approved
16 decided (1-9 homes)
86%
Major dwellings approved
14 decided (10+ homes)
88%
Change of use approved
33 decided
436
Total decisions
36 refused in the year to March 2026