Pantycabal, TUFTON, Clarbeston Road, Pembrokeshire, SA63 4TR Data via plota.co.uk

25/0929/PA - Full Approved

Proposal

Erection of agricultural portal framed building to cover existing yard and slurry Store Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Consultation
17 Feb 2026
✓
Received
5 Mar 2026
✓
Approved
24 Apr 2026

Approved on 24 Apr 2026 · Decision to be made by officer · Last checked 25 Jul 2026

Site constraints 14

Catchment Sir Thomas Picton / Bro Gwaun SharedCatchment Puncheston CPSAC_PhosphorusRiver_PhosphPolicy GN.22 Hard Rock ResourcesPolicy GN.1 General Development PolicyPolicy GN.2 Sustainable DesignPolicy SP.1 Sustainable DevelopmentPolicy SP.9 Welsh LanguagePolicy SP.16 The CountrysidePolicy GN.37 Protection & Enhancement of Biodiversity
Nutrient neutrality catchment: Afon Cleddau
New homes and overnight accommodation must show nutrient neutrality before approval.
Natural England advice: extra wastewater in these catchments harms protected habitats, so schemes must offset their nutrient load, usually through credits.
Agricultural land, grade 3b
Not best and most versatile land (grades 1, 2 and 3a). Source: the Predictive Agricultural Land Classification Map (Defra and Natural England, 2025; the Welsh Government's Predictive ALC Map 2 in Wales), a model rather than a site survey. A site survey can differ.
Where development of farmland is needed, policy prefers poorer land over the best and most versatile (grades 1, 2 and 3a). Three sources: Natural England's post-1988 field surveys, which are definitive where they exist; the Defra predictive map for England (2025) and the Welsh Government predictive map, modelled from the soil map with 3a and 3b split; and the 1970s provisional map, which planners and other services still show, coarser and with grade 3 undivided. Where the provisional and predicted grades disagree, treat the predicted grade as the current estimate and expect an application to carry its own survey.
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Catchment Sir Thomas Picton / Bro Gwaun SharedCouncil record
Recorded by the council for this site.
Council site ↗
Catchment Puncheston CPCouncil record
Recorded by the council for this site.
Council site ↗
SAC_PhosphorusCouncil record
Recorded by the council for this site.
Council site ↗
River_PhosphCouncil record
Recorded by the council for this site.
Council site ↗
Policy GN.22 Hard Rock ResourcesCouncil record
Recorded by the council for this site.
Council site ↗
Policy GN.1 General Development PolicyCouncil record
Recorded by the council for this site.
Council site ↗
Policy GN.2 Sustainable DesignCouncil record
Recorded by the council for this site.
Council site ↗
Policy SP.1 Sustainable DevelopmentCouncil record
Recorded by the council for this site.
Council site ↗
Policy SP.9 Welsh LanguageCouncil record
Recorded by the council for this site.
Council site ↗
Policy SP.16 The CountrysideCouncil record
Recorded by the council for this site.
Council site ↗
Policy GN.37 Protection & Enhancement of BiodiversityCouncil record
Recorded by the council for this site.
Council site ↗
Not affected
Outside flood zones 2 and 3 · No listed building at the site · No scheduled monument at the site

Checked on 6 October 2026. Historic England, the Environment Agency, Natural England, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area180 m² (1,938 sq ft)
Energy ratingE (47 out of 100), could reach B
PropertyDetached house, 8 habitable rooms
BuiltBefore 1900
HeatingBoiler and radiators, oil
WallsSandstone or limestone, as built, no insulation (assumed)

From the energy performance certificate lodged in March 2016, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in Pembrokeshire - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Full
Postcode
SA63 4TR
Received
5 Mar 2026
Validated
5 Mar 2026
Ward
Bro Gwaun
Case officer
Show
Target decision
29 Apr 2026
Decision
Conditionally Approved
Decision date
24 Apr 2026
Decision level
Decision to be made by officer
Applicant
Show

How this decision compares

Decided in 50 days from validation, about the council's usual 51 days. Approved, as 79% of agricultural works here are.

94%decided within 8 weeks
79%approved
63decided in the last year

Plota live figures for agricultural works decided by Pembrokeshire in the last twelve months, from validation. Pembrokeshire decision record →

Consultation & key dates

Site or press notice
17 Feb 2026
Statutory expiry
10 Mar 2026

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.