South Devon Railway Trust Heritage Railway And Premises Dart Bridge Road Buckfastleigh TQ11 0DZ Data via plota.co.uk

22/01561/COND1 - Discharge of Conditions 1 Pending Consideration

Proposal

Notification to Discharge Conditions 3 (Drainage & Surface Water Management Details), 4 (Remediation Strategy), 7 (LEMP & Landscape Strategy Plans) and 10 (Arboricultural Method Statement) in relation to the original application - Site wide landscaping works, erection of a locomotive restoration building (Use Class B2), alterations to internal access arrangements, and associated drainage infrastructure and works Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
28 Oct 2026
Decision
Expected by 23 Dec 2026

Under consideration

No decision has been issued yet. A decision is expected by 23 Dec 2026.

Site constraints 8

In flood zones plus climate change
Inside the extent flood zones 2 and 3 could reach with climate change: the Central allowance for the 2080s on rivers, the Upper End allowance for sea level rise to 2125. From rivers. Defences are not counted.
The Environment Agency flood map for planning. Councils use it to decide when a flood risk assessment and the sequential test are needed. It is indicative and does not show whether a particular property will flood.
Flood map ↗
Special area of conservation 168 m away: South Hams
Work nearby can need a habitats assessment.
Harm to a protected site is only accepted where there is no alternative and an overriding public interest.
Habitat network: Network Enhancement Zone 2
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Radon affected area, class 6
An estimated 30% or more of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
SSSI 168 m away: Buckfastleigh Caves SSSI
Natural England may need consulting, depending on what is proposed.
Sites of special scientific interest are the best wildlife and geological sites in the country. Development likely to harm one is rarely permitted.
National park 119 m away: Dartmoor
Outside the park; its setting can still be raised.
Landscape, scenic beauty and wildlife carry great weight, and major development is only allowed in exceptional circumstances.
Also on the record
Inside the Buckfastleigh built-up area; Natural England's Provisional ALC map (1:250,000, 1970s) had this area as grade 3, but it predates the buildings here and the current map does not class it as farmland.
Not affected
Outside flood zones 2 and 3 · Not green belt · No listed building at the site

Checked on 1 November 2026. Historic England, the Environment Agency, Natural England, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Teignbridge - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Discharge of Conditions 1
Postcode
TQ11 0DZ
Received
28 Oct 2026
Validated
28 Oct 2026
Ward
Ashburton And Buckfastleigh
Parish
BUCKFASTLEIGH
Case officer
Show
Target decision
23 Dec 2026
Applicant
Show
Agent
Walsingham Planning

Public comments

No public comments yet.

Last counted 19 Nov 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-15208482
Planning Portal ref
PP-15208482
Statutory expiry
23 Dec 2026
Env. assessment
No
Teignbridge
Planning Authority Score
6.1/10
Average
#102 of 296 overall
Relevant to this application:
Householder decisions

Teignbridge is faster than most councils at deciding householder applications: #39 of 296 on speed. Only 26% of applications have the time limit extended, well below the 41% national average - the council usually decides on time. Teignbridge is also one of the strictest councils - it refuses more householder applications than almost any other, with only 82% approved vs 90% nationally.

One of the strictest councils
only 82% approved vs 90% nationally
These figures are council-wide context, not a prediction for this application. View full council performance
Teignbridge decision statistics
Based on MHCLG data, the year to March 2026
80%
Overall approval rate
Below avg (87%) #262 of 296
82%
Householder approved
Below avg (90%) #270 of 296
80%
Decided in 8 weeks
Above avg (63%) #39 of 296
26%
Extended time limit
Below avg (41%) #37 of 296
60%
Minor dwellings approved
83 decided (1-9 homes)
100%
Major dwellings approved
13 decided (10+ homes)
69%
Change of use approved
13 decided
716
Total decisions
141 refused in the year to March 2026