Down Farm House Down Farm Lane Headbourne Worthy Winchester Hampshire SO22 6RG Data via plota.co.uk

26/00246/VAR - Variation of Permission Approved

Proposal

Variation to condition 2 (approved plan condition) on application Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
5 Feb 2026
✓
Validated
18 Feb 2026
✓
Approved
1 May 2026

Approved on 1 May 2026 · Delegated Decision · Last checked 2 Aug 2026

Documents 26

Plans & drawings 19

PDF 220.61.10310.GA 01 RESIDENTIAL CURTILAGE Revised Drawing · 30 Apr 2026 View ↗ PDF 220.61.21300.GA.04 PROPOSED ROOF PLAN Revised Drawing · 30 Apr 2026 View ↗ PDF 220.61.21100.GA.05 PROPOSED FIRST FLOOR PLAN Revised Drawing · 30 Apr 2026 View ↗ PDF 220.61.21000.GA 05 PROPOSED GROUND FLOOR PLAN Drawing Revised · 29 Apr 2026 View ↗ PDF 220.61.10310.GA 01 RESIDENTIAL CURTILAGE Revised Drawing · 29 Apr 2026 View ↗ PDF 220.61.41100.SEC 02 SECTIONS CC DD Revised Drawing · 29 Apr 2026 View ↗ PDF 220.61.31100.ELE 04 PROPOSED EAST AND WEST ELEVATIONS Revised Drawing · 29 Apr 2026 View ↗ PDF 220.61.31000.ELE 04 PROPOSED NORTH AND SOUTH ELEVATIONS Drawing Revised · 29 Apr 2026 View ↗ PDF 220.61.21300 AMENDED PROPOSED ROOF PLAN 03 Revised Drawing · 23 Apr 2026 View ↗ PDF 220.61.21100 AMENDED PROPOSED FIRST FLOOR PLAN 04 Revised Drawing · 23 Apr 2026 View ↗ PDF 220.61.21100 PROPOSED GROUND FLOOR PLAN 04 Superseded Drawing · 23 Apr 2026 View ↗ PDF 220.61.21100.GA PROPOSED FIRST FLOOR PLAN Superseded Drawing · 5 Feb 2026 View ↗ PDF 220.61.21300.GA PROPOSED ROOF PLAN Superseded Drawing · 5 Feb 2026 View ↗ PDF 220.61.31000.ELE PROPOSED NORTH AND SOUTH ELEVATIONS Superseded Drawing · 5 Feb 2026 View ↗ PDF 220.61.31100.ELE PROPOSED EAST AND WEST ELEVATIONS Superseded Drawing · 5 Feb 2026 View ↗ PDF 220.61.41000.SEC PROPOSED SECTION AA BB Drawing · 5 Feb 2026 View ↗ PDF 220.61.41100.SEC PROPOSED SECTIONS CC DD Superseded Drawing · 5 Feb 2026 View ↗ PDF 220.61.41200 PROPOSED SECTIONS EE FF Drawing · 5 Feb 2026 View ↗ PDF 220.61.21000.GA PROPOSED GROUND FLOOR PLAN Superseded Drawing · 5 Feb 2026 View ↗

All documents on the council site ↗

Associated applications 2

  • Part of

    FullApprovedcouncil archive

    Conditions 2 varied

    • VariationVariation to condition 2 (approved plan condition)This application26/00246/VAR

Site constraints 3

Nutrient neutrality catchment: Solent: Includes Chichester and Langstone Harbours SPA/Ramsar, Solent and Southampton Water SPA/Ramsar, Solent Maritime SAC, Portsmouth Harbour SPA/Ramsar
New homes and overnight accommodation must show nutrient neutrality before approval.
Natural England advice: extra wastewater in these catchments harms protected habitats, so schemes must offset their nutrient load, usually through credits.
Agricultural land, grade 3a
Best and most versatile land (grades 1, 2 and 3a). Source: the Predictive Agricultural Land Classification Map (Defra and Natural England, 2025; the Welsh Government's Predictive ALC Map 2 in Wales), a model rather than a site survey. Natural England's Provisional ALC map (1:250,000, 1970s) agrees.
Where development of farmland is needed, policy prefers poorer land over the best and most versatile (grades 1, 2 and 3a). Three sources: Natural England's post-1988 field surveys, which are definitive where they exist; the Defra predictive map for England (2025) and the Welsh Government predictive map, modelled from the soil map with 3a and 3b split; and the 1970s provisional map, which planners and other services still show, coarser and with grade 3 undivided. Where the provisional and predicted grades disagree, treat the predicted grade as the current estimate and expect an application to carry its own survey.
Habitat network: Network Expansion Zone
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Not affected
Outside flood zones 2 and 3 · Not green belt · No listed building at the site

Checked on 6 October 2026. Historic England, the Environment Agency, Natural England and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area271 m² (2,917 sq ft)
Energy ratingA (94 out of 100)
PropertyDetached house
Built2013
HeatingGround source heat pump, Underfloor heating, pipes in screed above insulation, electric
WallsAverage thermal transmittance 0.12 W/m²K

From the energy performance certificate lodged in February 2017, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in Winchester - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Winchester
Application type
Variation of Permission
Postcode
SO22 6RG
Received
5 Feb 2026
Validated
18 Feb 2026
Ward
THE WORTHYS WARD
Parish
Headbourne Worthy
Case officer
Show
Target decision
15 Apr 2026
Decision
Application Permitted
Decision date
1 May 2026
Decision level
Delegated Decision
Applicant
Show
Agent
Halton Planning Services

Consultation & key dates

Alt. reference
PP-14649306
Planning Portal ref
PP-14649306
Statutory expiry
15 Apr 2026
Env. assessment
No
Winchester
Planning Authority Score
4.5/10
Below average
#177 of 296 councils
Relevant to this application:
Householder decisions

Winchester is slower than most councils at deciding householder applications, ranking #213 out of 296. 50% of applications have the time limit extended, above the 41% national average. Householder applications are slightly more likely to be approved here (97%) than the national average (90%).

Slower than most councils
for householder decisions
These figures are council-wide context, not a prediction for this application. View full council performance
Winchester decision statistics
Based on MHCLG data, the year to March 2026
93%
Overall approval rate
Above avg (87%) #72 of 296
97%
Householder approved
Above avg (90%) #47 of 296
55%
Decided in 8 weeks
Below avg (63%) #213 of 296
50%
Extended time limit
Above avg (41%) #230 of 296
70%
Minor dwellings approved
63 decided (1-9 homes)
92%
Major dwellings approved
12 decided (10+ homes)
88%
Change of use approved
32 decided
918
Total decisions
60 refused in the year to March 2026

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.