HAWKWOOD PLANT NURSERY, 115 Hawkwood Crescent, Chingford, London, E4 7UH Data via plota.co.uk

262129 - Full Planning Approved

Proposal

Construction of a open-sided timber framed pavilion (3.5 metres in width and 3 metres in height). Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
10 Sept 2026
✓
Approved
4 Nov 2026

Approved on 4 Nov 2026 · Schedule 1 - Delegated · Last checked 5 Nov 2026

Site constraints 11

Green belt: London
Inappropriate development needs very special circumstances.
Green belt policy allows a short list of exceptions, such as limited extensions and replacement buildings. Anything else needs very special circumstances that clearly outweigh the harm. Some green belt land can count as grey belt, where it does not strongly serve the green belt's purposes. The council decides this in its green belt assessment or on each application, so we do not mark it here.
Read the government guidance ↗
Article 4 direction
Other Article 4 Direction Area. Named permitted development rights are withdrawn here.
An Article 4 direction withdraws particular permitted development rights, so work that would normally need no application needs one here. Not every council has published its directions.
Archaeological priority area: Waltham Forest APA 3.2 Epping Forest
An assessment or field evaluation may be asked for before ground works.
The council or Historic England considers archaeology likely here. A desk-based assessment, and sometimes trial trenching, can be asked for with the application.
Air quality management area: Waltham Forest AQMA
The council has declared the area as failing an air quality objective.
Schemes that add traffic, parking or combustion plant are assessed against the area's action plan and may need an air quality assessment.
Council record ↗
Special area of conservation 133 m away: Epping Forest
Work nearby can need a habitats assessment.
Harm to a protected site is only accepted where there is no alternative and an overriding public interest.
Habitat network: Other Priority Habitats - NEZ
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
SSSI 133 m away: Epping Forest SSSI
Natural England may need consulting, depending on what is proposed.
Sites of special scientific interest are the best wildlife and geological sites in the country. Development likely to harm one is rarely permitted.
Also on the record
National infrastructure project 1.6 km away: North London (Electricity Line) Reinforcement; Inside the Waltham Forest built-up area; Public transport access: PTAL 1a (very poor), TfL 2023, for the 100 m square; Priority habitat 17 m away: Traditional orchard.
Not affected
Outside flood zones 2 and 3 · No listed building at the site · No scheduled monument at the site

Checked on 2 November 2026. Historic England, the Environment Agency, Natural England, the Planning Inspectorate, Transport for London (public transport access levels, Powered by TfL Open Data, OGL v3.0, contains OS data © Crown copyright and database right 2025) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area2,097 m² (22,572 sq ft)
Energy ratingB (asset rating 27)
UseNon-residential Institutions: Education
HeatingHeating and Natural Ventilation

From the energy performance certificate lodged in March 2026, the latest held for this property, matched to this application by its address. The building may have changed since. View the certificate

Work with planning data?

Every application in Waltham Forest - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Full Planning
Postcode
E4 7UH
Received
10 Sept 2026
Validated
10 Sept 2026
Ward
Chingford Green
Case officer
Show
Target decision
5 Nov 2026
Decision
Approved (with Conditions & Informatives)
Decision date
4 Nov 2026
Decision level
Schedule 1 - Delegated
Applicant
Show

How this decision compares

Decided in 55 days from validation, about the council's usual 55 days. Approved, as 80% of extensions here are.

84%decided within 8 weeks
80%approved
1,828decided in the last year

Plota live figures for extensions decided by Waltham Forest in the last twelve months, from validation. Waltham Forest decision record →

Consultation & key dates

Statutory expiry
5 Nov 2026
Waltham Forest
Planning Authority Score
5.6/10
Average
#116 of 296 overall
Relevant to this application:
Householder decisions

Waltham Forest is faster than most councils at deciding householder applications: #80 of 296 on speed. Only 22% of applications have the time limit extended, well below the 41% national average - the council usually decides on time. Waltham Forest is also one of the strictest councils - it refuses more householder applications than almost any other, with only 79% approved vs 90% nationally.

One of the strictest councils
only 79% approved vs 90% nationally
These figures are council-wide context, not a prediction for this application. View full council performance
Waltham Forest decision statistics
Based on MHCLG data, the year to March 2026
76%
Overall approval rate
Below avg (87%) #284 of 296
79%
Householder approved
Below avg (90%) #284 of 296
75%
Decided in 8 weeks
Above avg (63%) #80 of 296
22%
Extended time limit
Below avg (41%) #25 of 296
49%
Minor dwellings approved
113 decided (1-9 homes)
100%
Major dwellings approved
8 decided (10+ homes)
50%
Change of use approved
56 decided
1,391
Total decisions
332 refused in the year to March 2026

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.