Chamber Court Winchester College College Street Winchester Hampshire Data via plota.co.uk

25/00354/LIS - Listed Building Approved

Proposal

Internal alterations to refurbish (including the installation of replacement services) and reconfigure the layout of Chambers Boarding House (comprising three separately listed Grade I buildings - Chamber Court, St Mary's College, St Mary's College Warden's Lodgings) and the insertion of three new window openings on the eastern side of Chamber Court. Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
20 Feb 2025
✓
Approved
16 Apr 2025

Approved on 16 Apr 2025 · Delegated Decision · Last checked 17 Nov 2026

Documents 52

Plans & drawings 38

PDF WCC-ACG-XX-00-DR-A-0001 P3 SITE LOCATION PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-1000 P6 EXISTING GROUND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-1001 P6 EXISTING FIRST FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-1002 P6 EXISTING SECOND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-1100 REV P6 PROPOSED DEMOLITION GROUND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-1101 REV P6 PROPOSED DEMOLITION FIRST FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-1103 REV P6 PROPOSED DEMOLITION SECOND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2000 P9 PROPOSED GROUND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-2001 P9 PROPOSED FIRST FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-2002 P9 PROPOSED SECOND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2021 P2 PROPOSED ENLARGED GROUND FLOOR PLAN - SHEET 1 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2022 P2 PROPOSED ENLARGED GROUND FLOOR PLAN - SHEET 2 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2023 P2 PROPOSED ENLARGED GROUND FLOOR PLAN - SHEET 3 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-2031 P3 PROPOSED ENLARGED FIRST FLOOR PLAN - SHEET 1 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-2032 P4 PROPOSED ENLARGED FIRST FLOOR PLAN - SHEET 2 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-2041 P2 PROPOSED ENLARGED SECOND FLOOR PLAN - SHEET 1 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-2042 P4 PROPOSED ENLARGED SECOND FLOOR PLAN - SHEET 2 Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2400 REV P2 GROUND FLOOR REFLECTED CEILING PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-2401 REV P2 FIRST FLOOR REFLECTED CEILING PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-2402 REV P2 SECOND FLOOR REFLECTED CEILING PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-2600 P3 FLOOR FINISHES GROUND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-01-DR-A-2601 P3 FLOOR FINISHES FIRST FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-2602 P3 FLOOR FINISHES SECOND FLOOR PLAN Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-ZZ-DR-A-4000 P2 EXISTING CONTEXTUAL EAST ELEVATION Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-ZZ-DR-A-4001 P2 PROPOSED CONTEXTUAL EAST ELEVATION Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-ZZ-DR-A-4002 P4 EXISTING ENLARGED EAST AND SOUTH ELEVATIONS Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-ZZ-DR-A-4003 P4 PROPOSED ENLARGED EAST AND SOUTH ELEVATIONS Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-DR-A-6022 REV P2 PROPOSED WINDOW DETAILS SHEET 01 (W-01) Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-DR-A-6023 REV P2 PROPOSED WINDOW DETAILS - SHEET 2 (W-02 & W-03) Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-DR-A-6041 REV B TYPICAL INTERNAL SECTION DETAILS SHEET 1 Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-00-DR-J-20100 P02 BUILDERS WORK IN CONNECTION LEVEL 00 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-01-DR-J-20100 P02 BUILDERS WORK IN CONNECTION LEVEL 01 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-02-DR-J-20100 P02 BUILDERS WORK IN CONNECTION LEVEL 02 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-00-DR-M-14100 P02 HEATING LEVEL 00 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-01-DR-M-14100 P02 HEATING LEVEL 01 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF J7346-MXF-ZZ-02-DR-M-14100 P02 HEATING LEVEL 02 LAYOUT Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-02-DR-A-6024 PP1 S22 ABLUTIONS - EXISTING SLIDING BOX SASH WINDOW ELEVATIONS Drawing · 20 Feb 2025 View ↗ PDF WCC-ACG-XX-00-DR-A-0100 REV P2 SITE BLOCK PLAN Drawing · 20 Feb 2025 View ↗

Consultation & comments 2

PDF WCC HISTORIC ENVIRONMENT Consultee Comment · 12 Mar 2025 View ↗
PDF Commenter’s name hidden Show Public Comment · 10 Mar 2025 View ↗

All documents on the council site ↗

Site constraints 11

Grade I listed: Chamber Court With Middle Gate St Mary's College
List entry 1296879 · 3 m away · 52 more listed buildings within 150 m (14 Grade I, 5 Grade II*, 33 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other 52 with distances
Historic England ↗
Nutrient neutrality catchment: Solent: Includes Chichester and Langstone Harbours SPA/Ramsar, Solent and Southampton Water SPA/Ramsar, Solent Maritime SAC, Portsmouth Harbour SPA/Ramsar
New homes and overnight accommodation must show nutrient neutrality before approval.
Natural England advice: extra wastewater in these catchments harms protected habitats, so schemes must offset their nutrient load, usually through credits.
Winchester conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
In flood zones plus climate change
Inside the extent flood zones 2 and 3 could reach with climate change: the Central allowance for the 2080s on rivers, the Upper End allowance for sea level rise to 2125. From rivers. Defences are not counted.
The Environment Agency flood map for planning. Councils use it to decide when a flood risk assessment and the sequential test are needed. It is indicative and does not show whether a particular property will flood.
Flood map ↗
Scheduled monument 56 m away: Winchester Cathedral Close
Its setting is a consideration for work nearby.
Nationally important archaeology protected by the Secretary of State. Work that affects the monument or its setting is rarely permitted.
Historic England ↗
Habitat network: Network Enhancement Zone 2
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Special area of conservation 231 m away: River Itchen
Work nearby can need a habitats assessment.
Harm to a protected site is only accepted where there is no alternative and an overriding public interest.
Also on the record
National park 129 m away: South Downs; SSSI 231 m away: Alresford Pond SSSI; National infrastructure project 1.1 km away: M3 Junction 9 Improvement; Inside the Winchester built-up area.
Not affected
Outside flood zones 2 and 3 · Not green belt

Checked on 9 November 2026. Historic England, the Environment Agency, Natural England, the Planning Inspectorate and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Winchester - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Winchester
Application type
Listed Building
Received
20 Feb 2025
Validated
20 Feb 2025
Ward
ST MICHAEL WARD
Parish
Winchester Town
Case officer
Show
Target decision
17 Apr 2025
Decision
Application Permitted
Decision date
16 Apr 2025
Decision level
Delegated Decision
Agent
Adams Hendry Consulting Ltd

How this decision compares

Decided in 55 days from validation, 11 days faster than Winchester's median of 66 for listed building consent. Approved, as 97% of listed building consent here are.

37%decided within 8 weeks
97%approved
106decided in the last year

Plota live figures for listed building consent decided by Winchester in the last twelve months, from validation. Winchester decision record →

Consultation & key dates

Alt. reference
PP-13627644
Planning Portal ref
PP-13627644
Statutory expiry
17 Apr 2025
Env. assessment
No
Winchester
Planning Authority Score
4.5/10
Below average
#177 of 296 overall
Relevant to this application:
Other decisions

Winchester is slower than most councils at deciding householder applications: #213 of 296 on speed. 50% of applications have the time limit extended, above the 41% national average. Householder applications are slightly more likely to be approved here (97%) than the national average (90%).

Slower than most councils
for householder decisions
These figures are council-wide context, not a prediction for this application. View full council performance
Winchester decision statistics
Based on MHCLG data, the year to March 2026
93%
Overall approval rate
Above avg (87%) #72 of 296
97%
Householder approved
Above avg (90%) #47 of 296
55%
Decided in 8 weeks
Below avg (63%) #213 of 296
50%
Extended time limit
Above avg (41%) #230 of 296
70%
Minor dwellings approved
63 decided (1-9 homes)
92%
Major dwellings approved
12 decided (10+ homes)
88%
Change of use approved
32 decided
918
Total decisions
60 refused in the year to March 2026