William Morris Gallery, LLOYD PARK Forest Road, Walthamstow, London, E17 4PP Data via plota.co.uk

251728 - Listed Building Consent Approved

Proposal

Listed building consent for internal refurbishment and restorative works to the ground and first floor areas of the William Morris Gallery following the removal of selected partition walls, internal furnishings and fixtures. Works include... Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
11 Jul 2025
✓
Approved
1 Sept 2025

Approved on 1 Sept 2025 · Delegated · Last checked 18 Oct 2026

Documents 82

Plans & drawings 50

PDF WMG_0700_4040 - First Floor Hall - Elevation A_B_C_D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4030 - Gallery 8 - Elevation D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4029 - Gallery 8 - Elevation C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4028 - Gallery 8 - Elevation B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4027 - Gallery 8 - Elevation A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4026 - Gallery 7 - Elevation F.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4025 - Gallery 7 - Elevation E.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4024 - Gallery 7 - Elevation D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4023 - Gallery 7 - Elevation C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4022 - Gallery 7 - Elevation B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4021 - Gallery 7 - Elevation A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4020 - Gallery 5 - Elevation D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4019 - Gallery 5 - Elevation C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4018 - Gallery 5 - Elevation B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4017 - Gallery 5 - Elevation A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4016 - Gallery 3 - Elevation F.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4015 - Gallery 3 - Elevation E.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4014 - Gallery 3 - Elevation D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4013 - Gallery 3 - Elevation C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4012 - Gallery 3 - Elevation B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4011 - Gallery 3 - Elevation A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4008 - Gallery 2 - Elevation C .pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4010 - Gallery 2 - Elevation E.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4009 - Gallery 2 - Elevation D .pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4007 - Gallery 2 - Elevation B .pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4006 - Gallery 2 - Elevation A .pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4005 - Gallery 1 - Elevation D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4004 - Gallery 1 - Elevation C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4003 - Gallery 1 - Elevation B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4002 - Gallery 1 - Elevation A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4001 - Hall - Elevation B_C_ D.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_4000 - Hall - Elevation A_C.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2005 - Gallery 7 and 8 Plan.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2004 - Zone Plan - Gallery 5 .pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2003 - Zone Plan - Gallery 2 and 3.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2002 - Zone Plan - Hall and Gallery 1 - Shop.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_1051 - Demolition First Floor Plan.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_1050 - Demolition Ground Floor Plan.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2006 - Zone Plan - Gallery 4.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1022_Existing_Proposed East Elevation.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1021_Existing_Proposed Rear Elevation.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1020_Existing_Proposed Front Elevation.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1014_Existing_Proposed Roof Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1013_Existing_Proposed Second Floor Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1012_Existing First Floor Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1011_Existing Ground Floor Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1010_Existing_Proposed Basement Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1001_Block Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1000_Location Plan.pdf Document · 14 Jul 2025 View ↗ PDF 0700_WMG_1023_Existing_Proposed West Elevation.pdf Document · 14 Jul 2025 View ↗

Other documents 28

PDF 250711_0700_WMG_LBC Schedule of Works.pdf Document · 14 Jul 2025 View ↗ PDF 250711_0700_WMG_LBC Supporting Document.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5063 - Details - G8 - SW8.04 - Bench.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5061 - Details - G8 - SW8.02 - Joinery B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5060 - Details - G8 - SW8.01 - Joinery A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5055 - Details - G7 - SW7.05 - Bench.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5052 - Details - G7 - SW7.02 - Wall Unit.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5051 - Details - G7 - SW7.01 - Interactive Wall Unit.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5050 - Details - G7 - SW7.01 - Interactive Wall Unit.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5034 - Details - G3 - SC3.02 - Wall case.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5032 - Details - G3 - SW3.05 - Label Rail.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5031 - Details - G3 - SW3.04 - Table.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5030 - Details - G3 - SW3.01 and SW3.02 - Plinth.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5043 - Details - G5 - SW5.04 - Bench.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5026 - Details - SW.FFL.1.01 - Picture Rail.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5025 - Details - SW2.07 - Picture Rail.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5024 - Details - G2 - SW2.08 - Bow Tie Cabinet.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5022 - Details - G2 - SW2.04 - Cabinet B.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5021 - Details - G2 - SW2.03 - Cabinet A.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5012 - Details - G1 - SW1.03 - Alcove Shelving.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5011 - Details - G1 - SW1.02 - Window Shelving.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5009 - Details - G1 - SW1.02 - Window Shelving.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5005 - Details - Hall - SW.0.05 - Flexible Shelving.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5000 - Details - Hall - SW.0.01 - Flexible Shelving.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_5013 - Details - G1 - SW1.04 - Alcove Locker.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2001 - Proposed First Floor GA.pdf Document · 14 Jul 2025 View ↗ PDF WMG_0700_2000 - Proposed Ground Floor GA.pdf Document · 14 Jul 2025 View ↗ PDF ApplicationFormRedacted.pdf Document · 14 Jul 2025 View ↗

All documents on the council site ↗

Site constraints 9

Grade II* listed: The Water House, Lloyd Park (William Morris Gallery)
List entry 1065620 · The pin is inside its outline · 1 more listed building within 150 m (1 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other one with distances
Historic England ↗
Lloyd Park conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Council document ↗
Article 4 direction
Other Article 4 Direction Area. Named permitted development rights are withdrawn here.
An Article 4 direction withdraws particular permitted development rights, so work that would normally need no application needs one here. Not every council has published its directions.
Designated open space
Borough-designated open space.
Loss of protected open space is resisted unless it is replaced by space of equal or better quality nearby.
Archaeological priority area
An assessment or field evaluation may be asked for before ground works.
The council or Historic England considers archaeology likely here. A desk-based assessment, and sometimes trial trenching, can be asked for with the application.
Air quality management area: Waltham Forest AQMA
The council has declared the area as failing an air quality objective.
Schemes that add traffic, parking or combustion plant are assessed against the area's action plan and may need an air quality assessment.
Council record ↗
Also on the record
National infrastructure project 1.7 km away: North London (Electricity Line) Reinforcement; Inside the Waltham Forest built-up area; Public transport access: PTAL 3 (moderate), TfL 2023, for the 100 m square.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 2 November 2026. Historic England, the Environment Agency, Natural England, the Planning Inspectorate, Transport for London (public transport access levels, Powered by TfL Open Data, OGL v3.0, contains OS data © Crown copyright and database right 2025) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Waltham Forest - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Listed Building Consent
Postcode
E17 4PP
Received
11 Jul 2025
Validated
11 Jul 2025
Ward
William Morris
Case officer
Show
Target decision
5 Sept 2025
Decision
Approved (with Conditions & Informatives)
Decision date
1 Sept 2025
Decision level
Delegated
Applicant
Show
Agent
Sam Jacob Studio

How this decision compares

Decided in 52 days from validation, 10 days faster than Waltham Forest's median of 62 for listed building consent. Approved, as 83% of listed building consent here are.

39%decided within 8 weeks
83%approved
21decided in the last year

Plota live figures for listed building consent decided by Waltham Forest in the last twelve months, from validation. Waltham Forest decision record →

Consultation & key dates

Statutory expiry
5 Sept 2025
Waltham Forest
Planning Authority Score
5.6/10
Average
#116 of 296 overall
Relevant to this application:
Other decisions

Waltham Forest is faster than most councils at deciding householder applications: #80 of 296 on speed. Only 22% of applications have the time limit extended, well below the 41% national average - the council usually decides on time. Waltham Forest is also one of the strictest councils - it refuses more householder applications than almost any other, with only 79% approved vs 90% nationally.

One of the strictest councils
only 79% approved vs 90% nationally
These figures are council-wide context, not a prediction for this application. View full council performance
Waltham Forest decision statistics
Based on MHCLG data, the year to March 2026
76%
Overall approval rate
Below avg (87%) #284 of 296
79%
Householder approved
Below avg (90%) #284 of 296
75%
Decided in 8 weeks
Above avg (63%) #80 of 296
22%
Extended time limit
Below avg (41%) #25 of 296
49%
Minor dwellings approved
113 decided (1-9 homes)
100%
Major dwellings approved
8 decided (10+ homes)
50%
Change of use approved
56 decided
1,391
Total decisions
332 refused in the year to March 2026