Rose Cottage Norton Road Norton East Sussex BN25 2UN Data via plota.co.uk

SDNP/25/04517/HOUS - Householder Approved

Proposal

Erection of first floor side extension Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
10 Nov 2025
✓
Validated
9 Dec 2025
✓
Approved
11 Mar 2026

Approved on 11 Mar 2026 · LA Delegated Decision · Last checked 3 Oct 2026

Site constraints 9

South Downs National Park
The park authority decides applications here. Great weight to conserving the landscape; major development restricted.
Landscape, scenic beauty and wildlife carry great weight, and major development is only allowed in exceptional circumstances.
South Heighton (Norton) conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Agricultural land, grade 3a
Best and most versatile land (grades 1, 2 and 3a). Source: the Predictive Agricultural Land Classification Map (Defra and Natural England, 2025; the Welsh Government's Predictive ALC Map 2 in Wales), a model rather than a site survey. Natural England's Provisional ALC map (1:250,000, 1970s) agrees.
Where development of farmland is needed, policy prefers poorer land over the best and most versatile (grades 1, 2 and 3a). Three sources: Natural England's post-1988 field surveys, which are definitive where they exist; the Defra predictive map for England (2025) and the Welsh Government predictive map, modelled from the soil map with 3a and 3b split; and the 1970s provisional map, which planners and other services still show, coarser and with grade 3 undivided. Where the provisional and predicted grades disagree, treat the predicted grade as the current estimate and expect an application to carry its own survey.
Habitat network: Lowland calcareous grassland
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
4 listed buildings within 150 m
Nearest: Barn of Norton Farm to North East of Hallands, Grade II, 49 m away · 4 Grade II
The site itself is not listed. Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show all 4 with distances
Historic England ↗
Also on the record
Public footpath 30 m away; Nature recovery project: Seaford to Eastbourne: Drink-in the Downs; Priority habitat 14 m away: Lowland calcareous grassland.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 2 November 2026. Historic England, the Environment Agency, Natural England, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Sales history 1

Last sold for £685,000 in December 2018. Detached house, freehold.

14 December 2018£685,000

Sale prices from HM Land Registry's price paid record, matched to this application by its address.

Building

Floor area119 m² (1,281 sq ft)
Energy ratingF (38 out of 100), could reach B
PropertyDetached house, 6 habitable rooms
Built1900 to 1929
HeatingBoiler and radiators, electric
WallsCavity wall, as built, no insulation (assumed)

From the energy performance certificate lodged in September 2018, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in South Downs - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Householder
Postcode
BN25 2UN
Received
10 Nov 2025
Validated
9 Dec 2025
Ward
Ouse Valley And Ringmer Ward
Parish
South Heighton Parish Council
Case officer
Show
Target decision
20 Mar 2026
Decision
Approved
Decision date
11 Mar 2026
Decision level
LA Delegated Decision
Applicant
Show
Agent
BPM

How this decision compares

Decided in 92 days from validation, 28 days slower than South Downs's median of 64 for householder applications. Approved, as 93% of householder applications here are.

42%decided within 8 weeks
93%approved
741decided in the last year

Plota live figures for householder applications decided by South Downs in the last twelve months, from validation. South Downs decision record →

Public comments

No public comments yet.

3 neighbours consulted · Last counted 3 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-14462812
Planning Portal ref
PP-14462812
Statutory expiry
3 Feb 2026
Env. assessment
No

Sale prices: Contains HM Land Registry data © Crown copyright and database right 2026. This data is licensed under the Open Government Licence v3.0.

Freehold boundary: © Crown copyright and database rights 2026, HM Land Registry. Polygons © Crown copyright and database rights 2026 Ordnance Survey 100026316. Conditions of use

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.