35 Green Street Neath Neath Port Talbot SA11 1DB Data via plota.co.uk

P2025/0510 - Full Plans Approved

Proposal

Existing bank facilities (night safe, ATM, external manifestation/artwork/branding/signs) to be removed and exterior of building made good with apertures infilled with stonework/brickwork to match existing - in association with bank branch closure. (heritage impact assessment submitted) Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
15 Jul 2025
✓
Validated
17 Jul 2025
✓
Consultation
25 Sept 2025
✓
Approved
6 Nov 2025

Approved on 6 Nov 2025 · Delegated Decision · Last checked 15 Oct 2026

Site constraints 6

Grade II listed: National Westminster Bank
List entry 11787 · 2 m away · 12 more listed buildings within 150 m (12 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other 12 with distances
Cadw ↗
Flood zone 3, rivers and sea
High chance: a 1 in 100 or greater annual chance from rivers, or 1 in 200 from the sea. Any development here needs a flood risk assessment. Defences are not counted.
The Environment Agency flood map for planning. Homes in zone 3 must also pass the sequential test. Surface water flooding is a separate map.
Flood map ↗
Neath Town Centre conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Also on the record
Registered park or garden 194 m away: Neath: Victoria Gardens; Coalfield, development low risk area.
Not affected
No scheduled monument at the site

Checked on 1 November 2026. Historic England, the Environment Agency, Natural England, the Mining Remediation Authority, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area313 m² (3,369 sq ft)
Energy ratingD (asset rating 86)
UseA1/A2 Retail and Financial/Professional services
HeatingAir Conditioning

From the energy performance certificate lodged in February 2023, the latest held for this property, matched to this application by its address. The building may have changed since. View the certificate

Work with planning data?

Every application in Neath - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Neath
Application type
Full Plans
Postcode
SA11 1DB
Received
15 Jul 2025
Validated
17 Jul 2025
Ward
Neath North
Parish
Neath Town Council
Case officer
Show
Target decision
14 Nov 2025
Decision
Approved
Decision date
6 Nov 2025
Decision level
Delegated Decision
Applicant
Show
Agent
Michael Laird Architects
Freehold owner
Show

How this decision compares

Decided in 112 days from validation, 58 days slower than Neath's median of 54 for full applications. Approved, as 97% of full applications here are.

56%decided within 8 weeks
97%approved
332decided in the last year

Plota live figures for full applications decided by Neath in the last twelve months, from validation. Neath decision record →

Public comments

No public comments yet.

1 neighbour consulted · Last counted 15 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-14178242
Planning Portal ref
PP-14178242
Neighbours
25 Sept 2025
Consultation
25 Sept 2025
Comments by
14 Oct 2025
Site or press notice
30 Sept 2025
Statutory expiry
10 Sept 2025
Env. assessment
No

Freehold boundary: © Crown copyright and database rights 2026, HM Land Registry. Polygons © Crown copyright and database rights 2026 Ordnance Survey 100026316. Conditions of use

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.

Freehold owner: Information produced by HM Land Registry. © Crown copyright 2026. Source: HM Land Registry, UK and overseas companies that own property in England and Wales, September 2026 release.