The Old Rectory Green Street Foxcote Radstock Somerset BA3 5YE Data via plota.co.uk

2026/1321/LBC - Listed Building Consent Approved

Proposal

Like for like replacement of modern windows to main house and barn. Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
10 Jul 2026
✓
Validated
13 Jul 2026
✓
Approved
21 Sept 2026

Approved on 21 Sept 2026 · Delegated Decision · Last checked 22 Sept 2026

Documents 20

All documents on the council site ↗

Site constraints 5

Grade II listed: Rectory Farmhouse
List entry 1307592 · 1 m away · 3 more listed buildings within 150 m (1 Grade II*, 2 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other 3 with distances
Historic England ↗
Agricultural land, grade 4
Poor quality farmland, not best and most versatile. Source: the Predictive Agricultural Land Classification Map (Defra and Natural England, 2025; the Welsh Government's Predictive ALC Map 2 in Wales), a model rather than a site survey. Natural England's Provisional ALC map (1:250,000, 1970s), which most planning maps still show, had this area as grade 3. The predicted grade is Defra's current estimate; only a site survey settles it.
Where development of farmland is needed, policy prefers poorer land over the best and most versatile (grades 1, 2 and 3a). Three sources: Natural England's post-1988 field surveys, which are definitive where they exist; the Defra predictive map for England (2025) and the Welsh Government predictive map, modelled from the soil map with 3a and 3b split; and the 1970s provisional map, which planners and other services still show, coarser and with grade 3 undivided. Where the provisional and predicted grades disagree, treat the predicted grade as the current estimate and expect an application to carry its own survey.
Habitat network: Network Expansion Zone
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Also on the record
Coalfield, development low risk area.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 6 October 2026. Historic England, the Environment Agency, Natural England, the Mining Remediation Authority, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area472 m² (5,081 sq ft)
Energy ratingF (33 out of 100), could reach D
PropertyDetached house, 9 habitable rooms
BuiltBefore 1900
HeatingBoiler and radiators, LPG
WallsSandstone or limestone, as built, no insulation (assumed)

From the energy performance certificate lodged in January 2022, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in Mendip - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Mendip
Application type
Listed Building Consent
Postcode
BA3 5YE
Received
10 Jul 2026
Validated
13 Jul 2026
Ward
Mendip Central And East Division
Parish
Hemington Parish Council
Case officer
Show
Target decision
18 Sept 2026
Decision
Approval
Decision date
21 Sept 2026
Decision level
Delegated Decision
Applicant
Show
Agent
Simon-Morray Jones Architects Ltd.

How this decision compares

Decided in 70 days from validation, 16 days slower than Mendip's median of 54 for extensions. Approved, as 89% of extensions here are.

66%decided within 8 weeks
89%approved
381decided in the last year

Plota live figures for extensions decided by Mendip in the last twelve months, from validation. Mendip decision record →

Public comments

No public comments yet.

3 neighbours consulted · Last counted 22 Sept 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-15066329
Planning Portal ref
PP-15066329
Comments by
12 Aug 2026
Statutory expiry
7 Sept 2026
Env. assessment
No

Freehold boundary: © Crown copyright and database rights 2026, HM Land Registry. Polygons © Crown copyright and database rights 2026 Ordnance Survey 100026316. Conditions of use

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.