St John's Concert Hall Smith Square London SW1P 3HA Data via plota.co.uk

26/07197/FULL - Full Planning Permission Application Pending

Proposal

Variation of conditions 5, 6a, 6c, 7 of planning permission dated 5th March 2026 (RN 25/04920/FULL) for the Change of use of caretaker flat to a community space within the crypt level, alterations and refurbishment including structural masonry repairs, refurbishment of the Main Hall, improvements to accessibility and circulation including lifts and reconfigured entrances and ramped access, replacement of mechanical and electrical services; new substation, new refuse store, PV panels and associated work. NAMELY, Revised mechanical and electrical works to reduce impacts on the existing roof and roof structure compared with the previously approved scheme, together with replacement windows to the crypt and installation of external lighting to the building. Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
21 Oct 2026
Decision
Expected by 16 Dec 2026

Under consideration

No decision has been issued yet. A decision is expected by 16 Dec 2026.

Documents 55

Plans & drawings 50

PDF PROPOSED CRYPT FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED MAIN HALL FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED THIRD FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED ROOF PLAN Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT MAIN HALL FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT GALLERY FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT THIRD FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT CRYPT FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT ROOF FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED MAIN HALL RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED CRYPT RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EAST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED SOUTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED PORTICO ELEVATIONS Drawing · 21 Oct 2026 View ↗ PDF PROPOSED WEST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED NORTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT PORTICOS ELEVATION Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT WEST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT SOUTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT EAST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT NORTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED SECTION B-B Drawing · 21 Oct 2026 View ↗ PDF PROPOSED SECTION A-A Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT SECTION B-B Drawing · 21 Oct 2026 View ↗ PDF STRIPOUT SECTION A-A Drawing · 21 Oct 2026 View ↗ PDF WINDOW TYPE 02 - NEW Drawing · 21 Oct 2026 View ↗ PDF WINDOW TYPE - SCOPE PLAN Drawing · 21 Oct 2026 View ↗ PDF TYPICAL WINDOW DETAILS Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY DETAILS - PLAN & RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY DETAIL 02 Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY DETAIL 03 Drawing · 21 Oct 2026 View ↗ PDF PROPOSED GALLERY DETAIL 01 Drawing · 21 Oct 2026 View ↗ PDF EXISTING/STRIP OUT GALLERY DETAIL Drawing · 21 Oct 2026 View ↗ PDF WINDOW TYPE 01 - NEW Drawing · 21 Oct 2026 View ↗ PDF FCU CASING TYPE 2 Drawing · 21 Oct 2026 View ↗ PDF FCU CASING TYPE 1 Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - PORTICOS ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - WEST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - EAST ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - SOUTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - NORTH ELEVATION Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - MAIN HALL RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - CRYPT RCP Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - ROOF FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - THIRD FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - CRYPT FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - GALLERY FLOOR PLAN Drawing · 21 Oct 2026 View ↗ PDF PROPOSED EXTERNAL LIGHTING - MAIN HALL FLOOR PLAN Drawing · 21 Oct 2026 View ↗

All documents on the council site ↗

Site constraints 11

Grade I listed: St. John's Smith Square
List entry 1236250 · The pin is inside its outline · 61 more listed buildings within 150 m (16 Grade II*, 45 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other 61 with distances
Historic England ↗
Flood zone 3, rivers and sea
High chance: a 1 in 100 or greater annual chance from rivers, or 1 in 200 from the sea. Any development here needs a flood risk assessment. Defences are not counted.
The Environment Agency flood map for planning. Homes in zone 3 must also pass the sequential test. Surface water flooding is a separate map.
Flood map ↗
Smith Square conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Council document ↗
Article 4 direction
Article 4 Basement Development Permitted Rights Removed. Named permitted development rights are withdrawn here.
An Article 4 direction withdraws particular permitted development rights, so work that would normally need no application needs one here. Not every council has published its directions.
Archaeological priority area: City of Westminster APA 1.1
An assessment or field evaluation may be asked for before ground works.
The council or Historic England considers archaeology likely here. A desk-based assessment, and sometimes trial trenching, can be asked for with the application.
Air quality management area: Westminster AQMA
The council has declared the area as failing an air quality objective.
Schemes that add traffic, parking or combustion plant are assessed against the area's action plan and may need an air quality assessment.
Council record ↗
National infrastructure project 116 m away: Thames Tideway Tunnel
The site is 116 m from the project boundary. Waste water treatment, decided. The project page says whether consent was granted. Also within 2 km: London Strategic Heat Main Project (at pre-application, 109 m).
Nationally significant infrastructure projects (power stations, electricity lines, pipelines, major roads and railways, harbours, airports and reservoirs) are consented by a Secretary of State under the Planning Act 2008, after an examination by the Planning Inspectorate, rather than by the council. The boundary is the one the Inspectorate consults on and can change as the scheme does. Projects are shown within 2 km of the site.
Planning Inspectorate project page ↗
Central activities zone
The core of central London in the London Plan.
Offices, culture and the other strategic functions of the centre take priority over new housing here.
Also on the record
World heritage site 128 m away: Victoria Tower Gardens; Inside the City of Westminster built-up area; Public transport access: PTAL 5 (very good), TfL 2023, for the 100 m square.
Not affected
Not green belt · No scheduled monument at the site

Checked on 28 October 2026. Historic England, the Environment Agency, Natural England, the Planning Inspectorate, Transport for London (public transport access levels, Powered by TfL Open Data, OGL v3.0, contains OS data © Crown copyright and database right 2025) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Westminster - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Application type
Full Planning Permission Application
Postcode
SW1P 3HA
Received
21 Oct 2026
Validated
21 Oct 2026
Ward
St James's
Case officer
Show
Target decision
16 Dec 2026
Applicant
Show
Agent
Burrell Foley Fischer LLP

Public comments

No public comments yet.

Last counted 28 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-15275751
Planning Portal ref
PP-15275751
Env. assessment
No
Westminster
Planning Authority Score
3.5/10
Below average
#221 of 296 councils
Relevant to this application:
Change of use

Westminster is slower than most councils at deciding householder applications, ranking #258 out of 296. Only 28% of applications have the time limit extended, well below the 41% national average - the council usually decides on time. Westminster is also one of the strictest councils - it refuses more householder applications than almost any other, with only 81% approved vs 90% nationally.

One of the strictest councils
only 81% approved vs 90% nationally
These figures are council-wide context, not a prediction for this application. View full council performance
Westminster decision statistics
Based on MHCLG data, the year to March 2026
86%
Overall approval rate
Below avg (87%) #201 of 296
81%
Householder approved
Below avg (90%) #277 of 296
44%
Decided in 8 weeks
Below avg (63%) #258 of 296
28%
Extended time limit
Below avg (41%) #46 of 296
83%
Minor dwellings approved
12 decided (1-9 homes)
67%
Major dwellings approved
3 decided (10+ homes)
81%
Change of use approved
133 decided
4,602
Total decisions
648 refused in the year to March 2026