34 Cloudesley Place, London, N1 0HZ Data via plota.co.uk

P2026/2392/LBC - Listed Building VALIDATED

Proposal

Replacement of roof coverings, gutter linings and flashings [Full planning application P2026/2385/FUL also submitted]. Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
10 Sept 2026
✓
Validated
15 Sept 2026
✓
Consultation
24 Sept 2026
Decision
Expected by 4 Nov 2026

Under consideration

No decision has been issued yet. Plota predicts a decision between 3 Nov 2026 and 11 Nov 2026, from Islington's recent extensions.

Comments are open until 17 Oct 2026

Comment on this application ↗

Associated applications 2

Site constraints 15

Article 4 directionCritical Drainage Group3_006Alexandra Palace viewing terrace to St Paul's CathedralBarnsbury and Laycock Liveable NeighbourhoodBarnsburyWithin 50m ofII
Grade II listed: Numbers 95b to 105 (Odd) and Railings Attached to Numbers 97, 103 and 105
List entry 1195653 · 16 m away · 20 more listed buildings within 150 m (20 Grade II)
Listed building consent is needed for work that affects the special interest of a listed building, inside or out, on top of planning permission. Setting can be a consideration for buildings nearby; there is no fixed radius.
Show the other 20 with distances
Historic England ↗
Barnsbury conservation area
Demolition needs planning permission and permitted development is restricted.
The council must give weight to preserving or enhancing the area's character and appearance. Not every council has published its boundaries as open data.
Council document ↗
Protected view corridor: 1A.2 Alexandra Palace viewing terrace to St Paul's Cathedral
Inside the landmark viewing corridor of a protected vista. A building that rises above the corridor's threshold height should be refused. How high that is depends on where along the view the site is.
The London Plan (policy HC4) designates strategic views, and the Mayor's London View Management Framework (March 2012) gives 13 of them a protected vista toward St Paul's Cathedral, the Palace of Westminster or the Tower of London. A vista has a threshold height that rises or falls with the line of sight. In the landmark viewing corridor, a building above it would harm the view and should be refused. In the wider setting consultation area around the corridor, a building above it is referred for consultation and its effect on the view is judged. The threshold changes along each view and is set out in the framework. A revised framework is out for consultation until 4 December 2026 and is not yet in force.
London View Management Framework ↗
Air quality management area: Islington AQMA
The council has declared the area as failing an air quality objective.
Schemes that add traffic, parking or combustion plant are assessed against the area's action plan and may need an air quality assessment.
Council record ↗
Article 4 directionCouncil record
Some permitted development rights are withdrawn. The direction is on the council's register but not published as open data.
Council site ↗
Critical Drainage Group3_006Council record
Recorded by the council for this site.
Council site ↗
Alexandra Palace viewing terrace to St Paul's CathedralCouncil record
Recorded by the council for this site.
Council site ↗
Barnsbury and Laycock Liveable NeighbourhoodCouncil record
Recorded by the council for this site.
Council site ↗
BarnsburyCouncil record
Recorded by the council for this site.
Council site ↗
Within 50m ofCouncil record
Recorded by the council for this site.
Council site ↗
IICouncil record
Recorded by the council for this site.
Council site ↗
Also on the record
Heritage at risk 33 m away: Angel; Inside the Islington built-up area; Public transport access: PTAL 5 (very good), TfL 2023, for the 100 m square; Town centre 22 m away: Angel.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 6 October 2026. Historic England, the Environment Agency, Natural England, Transport for London (public transport access levels, Powered by TfL Open Data, OGL v3.0, contains OS data © Crown copyright and database right 2025) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area142 m² (1,528 sq ft)
Energy ratingC (78 out of 100)
PropertySemi-detached house
Built2009
HeatingBoiler and radiators, mains gas
WallsAverage thermal transmittance 0.27 W/m²K

From the energy performance certificate lodged in January 2010, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in Islington - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Islington
Application type
Listed Building
Postcode
N1 0HZ
Received
10 Sept 2026
Validated
15 Sept 2026
Ward
Barnsbury
Case officer
Show
Target decision
4 Nov 2026
Applicant
Show

Decision outlook

Day 24 of the 56-day target. Islington usually decides extensions by day 52.

Day 2432 days to the 56-day target
60%decided within 8 weeks
94%approved
663decided in the last year

Plota live figures for extensions decided by Islington in the last twelve months, from validation. Islington decision record →

Consultation & key dates

Alt. reference
PP-15217722_C
Comments by
17 Oct 2026
Site or press notice
24 Sept 2026
Statutory expiry
10 Oct 2026
Islington
Planning Authority Score
2.9/10
Poor
#237 of 296 councils
Relevant to this application:
Other decisions

Islington is slower than most councils at deciding householder applications, ranking #260 out of 296. 53% of applications have the time limit extended, above the 41% national average. Householder applications are slightly more likely to be approved here (93%) than the national average (90%).

Slower than most councils
for householder decisions
These figures are council-wide context, not a prediction for this application. View full council performance
Islington decision statistics
Based on MHCLG data, the year to March 2026
89%
Overall approval rate
Above avg (87%) #132 of 296
93%
Householder approved
Above avg (90%) #130 of 296
43%
Decided in 8 weeks
Below avg (63%) #260 of 296
53%
Extended time limit
Above avg (41%) #241 of 296
89%
Minor dwellings approved
499 decided (1-9 homes)
100%
Major dwellings approved
1 decided (10+ homes)
89%
Change of use approved
19 decided
1,488
Total decisions
167 refused in the year to March 2026

Freehold boundary: © Crown copyright and database rights 2026, HM Land Registry. Polygons © Crown copyright and database rights 2026 Ordnance Survey 100026316. Conditions of use

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.