Unit 4 To 6 4 - 8 Penallta Road Ystrad Mynach Hengoed CF82 7AP Data via plota.co.uk

26/0701/RET - Retain Development Already Carried Out Awaiting decision

Proposal

Retain siting of an InPost Parcel Locker Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
20 Oct 2026
✓
Validated
21 Oct 2026
✓
Consultation
21 Oct 2026
Decision
Expected by 16 Dec 2026

Under consideration

No decision has been issued yet. Plota predicts a decision around 13 Dec 2026, from Caerphilly's recent commercial premises.

Comments are open until 11 Nov 2026

Comment on this application ↗

Site constraints 3

Flood zone 3, rivers and sea
High chance: a 1 in 100 or greater annual chance from rivers, or 1 in 200 from the sea. Any development here needs a flood risk assessment. Defences are not counted.
The Environment Agency flood map for planning. Homes in zone 3 must also pass the sequential test. Surface water flooding is a separate map.
Flood map ↗
Radon affected area, class 5
An estimated 10 to 30% of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
Also on the record
Coalfield, development low risk area.
Not affected
No listed building at the site · No scheduled monument at the site

Checked on 26 October 2026. Historic England, the Environment Agency, Natural England, the Mining Remediation Authority, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Building

Floor area186 m² (2,002 sq ft)
Energy ratingC (asset rating 64)
UseRetail/Financial and Professional Services
HeatingAir Conditioning

From the energy performance certificate lodged in September 2023, the latest held for this property. The building may have changed since. View the certificate

Work with planning data?

Every application in Caerphilly - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Caerphilly
Application type
Retain Development Already Carried Out
Postcode
CF82 7AP
Received
20 Oct 2026
Validated
21 Oct 2026
Ward
Ystrad Mynach
Case officer
Show
Target decision
16 Dec 2026
Decision level
Delegated
Applicant
Show
Agent
NL Jones Planning

Decision outlook

Day 7 of the 56-day target. Caerphilly usually decides commercial premises by day 53.

Day 749 days to the 56-day target
68%decided within 8 weeks
81%approved
98decided in the last year

Plota live figures for commercial premises decided by Caerphilly in the last twelve months, from validation. Caerphilly decision record →

Public comments

No public comments yet.

8 neighbours consulted · Last counted 26 Oct 2026

Read the comments on the council site ↗

Consultation & key dates

Alt. reference
PP-15236047
Planning Portal ref
PP-15236047
Neighbours
21 Oct 2026
Consultation
21 Oct 2026
Comments by
11 Nov 2026
Site or press notice
22 Oct 2026
Statutory expiry
16 Dec 2026
Env. assessment
No

Energy performance: Energy performance certificates from the Energy Performance of Buildings Register, Ministry of Housing, Communities and Local Government. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2026.