Boyes Transport Yard, Longcross, Near Zeals, Warminster, BA12 6LL Data via plota.co.uk

PL/2026/02163 - Full planning permission Refused

Proposal

Retrospective planning application for retention of welfare facilities and revisions to workshop building permitted by planning permission . Data via plota.co.uk

View original council record ↗Last checked

Application progress

✓
Received
13 Apr 2026
✗
Refused
8 Jun 2026
Appeal
Not lodged

Refused on 8 Jun 2026 · Last checked 21 Aug 2026

Documents 29

All documents on the council site ↗

Associated applications 2

  • Part of

    FullApprovedcouncil archive
    • FullRetrospective planning application for retention of welfare facilities and revisions…RefusedThis applicationPL/2026/02163

Site constraints 4

Agricultural land, grade 2
Best and most versatile land (grades 1, 2 and 3a). Source: the Predictive Agricultural Land Classification Map (Defra and Natural England, 2025; the Welsh Government's Predictive ALC Map 2 in Wales), a model rather than a site survey. Natural England's Provisional ALC map (1:250,000, 1970s) agrees.
Where development of farmland is needed, policy prefers poorer land over the best and most versatile (grades 1, 2 and 3a). Three sources: Natural England's post-1988 field surveys, which are definitive where they exist; the Defra predictive map for England (2025) and the Welsh Government predictive map, modelled from the soil map with 3a and 3b split; and the 1970s provisional map, which planners and other services still show, coarser and with grade 3 undivided. Where the provisional and predicted grades disagree, treat the predicted grade as the current estimate and expect an application to carry its own survey.
Habitat network: Network Expansion Zone
Where habitat is joined up enough to work as a network. Context, not a constraint on its own.
Radon affected area, class 6
An estimated 30% or more of homes reach the radon action level. Indicative for the 1 km square, which takes the highest class found in it; a radon test gives the answer for a building.
From the British Geological Survey and UK Health Security Agency indicative atlas. Under building regulations, as the BRE guide BR 211 (2023) sets out, new buildings and extensions need basic radon protection from class 3 in England and Wales and from class 2 in Scotland, and full protection from class 5. The class at the site itself, from the detailed BGS map, decides which.
UKHSA radon ↗
National landscape about 16 m away: Cranborne Chase & West Wiltshire Downs
Outside the landscape; its setting can still be raised.
Previously an area of outstanding natural beauty, which is still the designation in law. Since 2023 authorities must seek to further its purpose, not merely have regard to it.
Not affected
Outside flood zones 2 and 3 · Not green belt · No scheduled monument at the site

Checked on 6 October 2026. The pin for this application is the centre of its postcode rather than the building, so distances to nearby designations are measured from the postcode and can be out by the width of the postcode area. Historic England, the Environment Agency, Natural England, the British Geological Survey and UK Health Security Agency (radon, contains BGS materials © UKRI) and council datasets, Open Government Licence. A boundary can run through a site and the council holds the definitive record: confirm with the council before relying on this.

Work with planning data?

Every application in Wiltshire - and every UK council - as a live feed, an API, or a bulk CSV export.

About Plota's data service

Important details

Council
Wiltshire
Application type
Full planning permission
Postcode
BA12 6LL
Received
13 Apr 2026
Validated
13 Apr 2026
Ward
Mere ED
Parish
Zeals CP
Case officer
Show
Target decision
8 Jun 2026
Decision
Refuse
Decision date
8 Jun 2026

How this decision compares

Decided in 56 days from validation, 7 days faster than Wiltshire's median of 63 for commercial and major works. Refused, as 9% of commercial and major works here are.

45%decided within 8 weeks
91%approved
123decided in the last year

Plota live figures for commercial and major works decided by Wiltshire in the last twelve months, from validation. Wiltshire decision record →

Public comments

9comments received
4 objecting3 neutral2 supporting

44% object · below the UK average of 74%

Last counted 21 Aug 2026

Read the comments on the council site ↗

Consultation & key dates

Comments by
11 May 2026
Wiltshire
Planning Authority Score
3.9/10
Below average
#203 of 296 councils
Relevant to this application:
Householder decisions

Wiltshire is slower than most councils at deciding householder applications, ranking #225 out of 296. The council extends the time limit on 55% of applications - one of the highest rates in England. Expect your application to take longer than the standard deadline. Householder applications are slightly more likely to be approved here (96%) than the national average (90%).

Frequently extends decision deadlines
expect longer than the statutory limit
These figures are council-wide context, not a prediction for this application. View full council performance
Wiltshire decision statistics
Based on MHCLG data, the year to March 2026
93%
Overall approval rate
Above avg (87%) #71 of 296
96%
Householder approved
Above avg (90%) #65 of 296
53%
Decided in 8 weeks
Below avg (63%) #225 of 296
55%
Extended time limit
Above avg (41%) #252 of 296
78%
Minor dwellings approved
339 decided (1-9 homes)
90%
Major dwellings approved
48 decided (10+ homes)
92%
Change of use approved
160 decided
3,659
Total decisions
256 refused in the year to March 2026